..

परमाणु चिकित्सा एवं विकिरण चिकित्सा

पांडुलिपि जमा करें arrow_forward arrow_forward ..

आयतन 13, मुद्दा 9 (2022)

छोटी समीक्षा

Examination of The Dose-Volume-Result Interaction in Pneumonitis Following Stereotactic Thoracic Radioimmunotherapy with Checkpoint Obstacles

Brennan Aarts

Thoracic stereotactic body radiation treatment (SBRT) is widely utilized in mix with safe designated spot bar (ICB). While current proof proposes that the event of pneumonitis as a symptom of the two medicines isn't upgraded for the mix, the portion volume connection stays indistinct. We examine portion volume-impact relationships for pneumonitis after joined SBRT + ICB. We broke down quiet clinical qualities and dosimetric information for 42 informational collections for thoracic SBRT with ICB treatment (13) and without (29). Portion volumes were changed over into 2 Gy identical dosages (EQD2), considering dosimetric correlation of various fractionation systems. Pneumonitis volumes were depicted and it were dissected to relate DVHs. We saw a shift towards lower portions for joined SBRT + ICB treatment, upheld by a pattern of more modest regions under the bend (AUC) for SBRT+ ICB (middle AUC 1337.37 versus 5799.10, p = 0.317). We present a DVH-based portion volume-impact relationship technique and noticed enormous pneumonitis volumes, even with two-sided degree in the SBRT + ICB bunch. We reason that further examinations utilizing this strategy with improved factual power are expected to explain whether changes of the radiation portion imperatives are expected to more readily gauge dangers of pneumonitis after the blend of SBRT and ICB

छोटी समीक्षा

Execution Assessment as Indicated By Polymer Embodiment Qualities of Eco-Accommodating Plastic Gamma-Beam Safeguard

Krohn Zhang

To dispense with the openness of clinical staff to radiopharmaceuticals during atomic medication tests, another cycle innovation was proposed for assembling gamma-beam safeguards utilized in atomic medication. On account of assembling the current gamma-beam safeguard, a technique for expanding the substance of the protecting material in the blended material is utilized to further develop the protecting presentation. Nonetheless, further developing the safeguarding execution by essentially expanding the substance of the protecting material is incomprehensible. Consequently, this study plans to introduce the ideal circumstances for working on the miscibility between composite materials. Following the extra blending of barium sulfate and bismuth oxide with tungsten, a needle safeguard was created through a plastic infusion form process. At the point when tungsten was exclusively utilized or in blend with other safeguarding materials, polymer exemplification happened, and miscibility between composite materials was noticed. In light of these outcomes, the ideal circumstances as far as eco-accommodating materials, monetary attainability, and improvement in safeguarding not set in stone. The discoveries of this study uncover that when tungsten and the polymers are joined, the polymer epitome is ideal, the particles are consistently scattered, and the protecting exhibition is fundamentally gotten to the next level. With a 99mTc source, a 6.9% improvement in the safeguarding execution is accomplished contrasted and the utilization of lead.

मामला का बिबरानी

18F-FDG PET/CT Revealed of Rare Primary Lyphoepithelionma-Like Carcinoma of the Lung: A Case Report and Literature Review

Xue Liu, Tao Jiang and Bao Zhang

We present a case of a 44-year-old woman was hospitalized for one year with intermittent coughing and expectoration. She has no history of smoking or previous medical conditions. DNA test positive for Epstein-Barr virus. Chest computed tomography (CT) showed a soft tissue mass in the left lower lobe of the lung and non-uniformity of image density. Part of the bronchus in the lower lobe of the left lung was compressed and occluded. On contrast-enhanced CT, the mass was inhomogeneously enhanced. Fluorine-18-fluorodeoxyglucose positron emission tomography/ CT (18F-FDG PET/CT) revealed the mass had significant uptake of FDG and maximum standard uptake value (SUVmax) was 10.7. The subsequent histopathologic examination confirmed the diagnosis of a primary lung lyphoepithelionma-like carcinoma (LELC). The patient was treated with chemotherapy.

जर्नल हाइलाइट्स

में अनुक्रमित

arrow_upward arrow_upward